Created with Pixso. OPC-UA Electronic Batch Records 10ml Sterilizing Filling Sealing Ampoule Line, 10000 pcs/h ≤1% Breakage Rate AGF-11S

OPC-UA Electronic Batch Records 10ml Sterilizing Filling Sealing Ampoule Line, 10000 pcs/h ≤1% Breakage Rate AGF-11S

Brand Name: ECER
Model Number: AGF-10-10000
MOQ: 1 Set
Price: USD 45000-120000 / Set
Delivery Time: 45-60 Working Days
Payment Terms: T/T, L/C
Detail Information
Place of Origin:
China
Certification:
CE, ISO 9001, GMP
Ampoule Size Range:
10ml
Production Speed:
10000 Pcs/h
Washing Method:
Vertical Ultrasonic + Independent Water/air
Sterilization:
Dry-heat 310-325°C Laminar Flow
Filling Heads:
10 Ceramic Piston Pumps
Filling Accuracy:
±0.5% - ±2%
Sealing Method:
Oxygen-natural Gas Flame Pull-seal
Clarity Rate:
>99%
Breakage Rate:
≤1%
Control System:
PLC + 10-inch HMI Touchscreen
Power Supply:
380V / 50Hz, 3-phase (customizable)
Main Material:
316L Stainless Steel Contact Parts
Packaging Details:
Fumigated Plywood Export Crate with VCI Film
Supply Ability:
10 Sets per Month
Highlight:

OPC-UA ampoule filling machine 10000 pcs/h

,

sterilizing ampoule sealing line ≤1% breakage

,

electronic batch records ampoule machine AGF-11S

Product Description
Problem

Conventional ampoule washing stations using shared water recirculation systems accumulate particulate loading throughout production shifts, with turbidity increasing from <1 NTU to >15 NTU after 4 hours of continuous operation for 10ml ampoules. Progressive water quality degradation means the last ampoules washed in a shift receive significantly less effective cleaning than the first.

Cause

Closed-loop water recirculation without continuous bleed-and-feed refresh allows cumulative particle loading following exponential growth kinetics: C(t) = C₀ * e^(kt), where k ≈ 0.15-0.25 hour⁻¹ for 10ml glass ampoule washing. After 4 hours, particulate concentration is 1.8-2.7* the initial level, exceeding USP <788> limits for Water for Injection of 25 particles/mL ≥10μm.

Solution

Each washing station in our 10ml ampoule line uses single-pass WFI and compressed air—no recirculation, no accumulation of particulate loading, and no degradation of cleaning performance over shift duration. Fresh 0.2μm-filtered WFI at 65°C ±2°C is supplied to every rinsing needle at constant 2.5 bar pressure, with conductivity monitoring (<1.3 μS/cm at 25°C) providing real-time water quality verification per USP <645>.

Key Features
  • Laminar-Flow Hot Air Circulation: Uniform 0.5 m/s ±0.05 m/s face velocity across the entire sterilization tunnel cross-section, verified by 16-point anemometer grid mapping during IQ/OQ. ISO 5 particle classification maintained throughout the tunnel length under dynamic operating conditions.
  • Servo-Driven ±0.5% Filling Accuracy: Ceramic piston pumps (Al₂O₃ 99.7%) with 17-bit absolute encoders deliver closed-loop volumetric dosing. Integrated in-line checkweighing at 0.1mg resolution provides 100% fill verification with automatic rejection of out-of-specification ampoules.
  • Synchronized Filling and Flame Sealing: Servo-controlled Z-axis nozzle retraction and burner ignition synchronized at 1ms update rate with ±0.5ms timing precision. 2-color IR pyrometer (200Hz) provides real-time glass temperature feedback for dynamic burner height adjustment at 0.05mm resolution.
  • Automatic Ampoule Feeding and Transfer: Servo-driven starwheel with individual spring-loaded 3-point centering pockets self-adjusts to actual ampoule diameter (±0.5mm tolerance). Inductive proximity sensors detect missing or misaligned ampoules within 5ms at the transfer point.
  • HMI Integrated Line Control: S7-1500 PLC with 10-inch color touchscreen stores 50 product recipes. OPC-UA server capability logs all critical process parameters at 10Hz to an onboard SQL database with auto-generated 21 CFR Part 11 compliant electronic batch records.
  • Automatic Fault Display and Diagnostics: Multi-sensor jam detection combining photoelectric sensors (0.1ms), inductive pocket sensors and 200fps camera frame-difference analysis triggers localized emergency stop within 3ms. HMI displays root-cause diagnostics with guided recovery procedures.
Technical Specifications
ParameterSpecification
Ampoule Compatibility10ml (GB 2637 / ISO 9187 Type I borosilicate glass)
Production Capacity10000 ampoules per hour
Washing MethodVertical ultrasonic (31kHz) + independent WFI water/air rinsing
Sterilization Temperature310-325°C, laminar-flow HEPA H14 filtered
Filling Accuracy±0.5% (servo ceramic piston, 10ml fill volume)
Filling Heads10 ceramic piston pumps, individually servo-driven
Sealing MethodOxygen-natural gas flame, synchronized pull-seal with IR pyrometer feedback
Clarity Rate>99% (post-wash inline camera inspection, 360° rotation capture)
Breakage Rate≤1% (whole-line, validated across 1M+ ampoules)
Control System S7-1500 PLC + 10-inch HMI touchscreen, 50-recipe storage
Power Supply380V / 50Hz, 3-phase (60Hz / 440V customizable)
Line Footprint7500 x 1,800 x 2,200 mm (L x W x H)
Cleanroom ClassificationISO 7 (Class 10,000) room; filling zone ISO 5 (Class 100) laminar
Selection Guide

For 10ml ampoule production at 10000 pcs/h, this model suits facilities producing 80-160k ampoules per single/double shift. Select this capacity tier when your annual demand falls between 20-40 million ampoules. For start-up or clinical trial supply with lower initial volumes, consider our 10000 pcs/h variant. For high-volume commercial manufacturing, step up to the 20000 pcs/h model. Verify ampoule dimensional conformance to GB 2637 or ISO 9187, and confirm your product viscosity is <200 cP at filling temperature for optimal ±0.5% accuracy.

Applications

Suitable for pharmaceutical injectable products requiring aseptic processing in 10ml ampoule format. Ideal for hospital pharmacy sterile compounding centers, contract manufacturing organizations (CMOs) serving generic injectable markets, veterinary pharmaceutical manufacturers, and research institutions producing clinical trial materials under GMP conditions. Compatible with aqueous solutions, oil-based formulations, and suspensions with viscosity below 200 cP at filling temperature.

FAQ

Q: What preventive maintenance is required?
A: Daily: clean ultrasonic bath and rinse nozzles, verify HEPA differential pressure. Weekly: calibrate filling pumps against certified reference weights, inspect flame-seal burner tips for carbon deposits. Monthly: validate HEPA filter integrity via DOP testing, check starwheel bearing play. Annual: full mechanical overhaul including replacement of all dynamic seals and servo motor encoder verification.

Q: Is the line compatible with CIP/SIP systems?
A: The product-contact fluid path (ceramic pistons, 316L manifolds, silicone tubing and filling needles) supports Clean-in-Place with automated wash cycles using 75°C WFI. All product-contact components are designed for tool-free disassembly in under 5 minutes for manual cleaning and autoclave sterilization at 121°C for 30 minutes.

Q: What glass particulate control measures are in place?
A: Five-layer defense: (1) dual-frequency ultrasonic washing removes >99.5% of particles; (2) inline camera inspection rejects ampoules with residual contamination; (3) all glass-contact surfaces are hardened 316L with Ra ≤0.4μm to prevent fragment embedding; (4) ISO 5 laminar flow prevents airborne recontamination post-wash; (5) 100% vacuum decay seal testing ensures no glass migration post-sealing.

Q: What utility requirements must the facility provide?
A: Water for Injection (WFI) at 2.5 bar and 65°C ±2°C with <1.3 μS/cm conductivity; compressed air at 6 bar, oil-free, filtered to 0.01μm with dew point ≤-40°C; natural gas (or propane) at 50 mbar for flame sealing; 380V/50Hz 3-phase electrical supply, 25-45 kVA depending on tunnel length; clean dry compressed air for pneumatics at 6 bar. All utility consumption rates are specified in the installation qualification documentation.